Description
Indoor Wall Mounted Units:
| Indoor unit | RAS– | B10N3KV2-E | |
| Air Flow(max) | m3/h – l/s | C | 516 – 143 |
| Sound pressure level (h/l) | dB(A) | C | 38/26 |
| Sound power level (h) | dB(A) | C | 53 |
| Air Flow(max) | m3/h – l/s | H | 570 – 158 |
| Sound pressure level (h/l) | dB(A) | H | 39/28 |
| Sound power level (h/l) | dB(A) | H | 54 |
| Dimensions (HxWxD) | mm | 275x790x225 | |
| Weight | kg | 10 | |
| Flare connections (gas – liquid) | inch | 3/8 – 1/4 |
OUTDOOR UNIT:
| PRODUCT CODE | RAS-4M27S3AV-E |
| OPERATION DATA | |
| COOLING CAPACITY | 8kW |
| HEATING CAPACITY | 9kW |
| EER/COP RATED | |
| COOL | 3.5 |
| HEAT | 4.67 |
| CHARGELESS LENGTH | 25m |
| MAXIMUM PIPE LENGTH | 75m |
| MAXIMUM HEIGHT DIFFERENCE | 25m |
| OPERATING RANGE | |
| COOL | 5 ~ 43 |
| HEAT | -10 ~ 24 |
| WEIGHT | 72Kg |
| DIMENSIONS (H x W x D) | 890 x 800 x 320mm |
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.