Description
Specification:
| INDOOR UNIT with Infrared Controller | SRK20ZS-WF/B/T | |
| UK Cooling | kW | 1.9 |
| UK Sensible Cooling | kW | 1.81 |
| Cooling Range (Nominal) | kW | 0.9 to 2.9 |
| S.E.E.R , EER, Energy Label | 8.5, 4.55, A+++ | |
| Heating Range (Nominal) | kW | 0.9 to 4.3 |
| S.C.O.P (Energy Label) | 4.6, 4.58, A++ | |
| INDOOR UNIT | ||
| Exterior Dimensions (H x W x D) | mm | 290 x 870 x 230 |
| Net Weight | kg | 9.5 |
| Air Flow (H/M/L) Cooling | m3/m | 9.3 / 7.0 / 5.9 |
| Air Flow (H/M/L) Heating | m3/m | 10.0 / 8.5 / 6.5 |
| Sound Pressure Level (H/M/L) Cooling | db(A) | 34 / 25 / 22 |
| Sound Pressure Level (H/M/L) Heating | db(A) | 36 / 29 / 23 |
| ELECTRICAL DATA | ||
| Power Source Rating MCB | A | 16 |
| Mains Power To | Outdoor | 230V/1ph/50Hz |
| Interconnecting Wires (Dia) | (mm2) | 3+E (1.5) |
| Start Current / Max Running Current | A | 2.9 / 9 |
| INSTALLATION/REFRIGERANT | ||
| Ref. Piping Size o.d inches (mm) | Liquid | 1/4 (6.35) |
| Suction | 3/8 (9.52) | |
| Ref. Max Piping Length | m | 20 |
| Vertical Height Difference (Max)*Outdoor Unit Above/Below Indoor Unit | m | 10 / 10 |
| Additional Refrigerant | g/m | 20 |
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.