Description
Perfect for areas where you want concealed air conditioning, the Mitsubishi SRR systems is designed for applications mounted above a ceiling. Compared to the previous model, it is even thinner at only 200 mm instead of 230 mm, the further reduction in height allows installation applications of unit in false ceilings. With the option of either a hard wired controller or a Infrared controller kit this system offers the user flexibility of use. The SRR range can be used for residential or commercial applications such as office and other work environments and operate at a low noise level.
Technical Specifications:
| Nominal cooling capacity | kW | 2.5 | |
| Nominal heating capacity | kW | 3.4 | |
| Sound power level | Cooling | dB(A) | 56 |
| Heating | dB(A) | 59 | |
| Sound pressure level | Cooling(Hi/Me/Lo/Ulo) | dB(A) | 37 / 33 / 30 / 24 |
| Heating(Hi/Me/Lo/Ulo) | dB(A) | 40 / 37 / 34 / 28 | |
| Air flow | Cooling(Hi/Me/Lo/Ulo) | m3/min | 9.5 / 8.5 / 6.5 / 4.5 |
| Heating(Hi/Me/Lo/Ulo) | m3/min | 10.0 / 9.0 / 8.0 / 6.0 | |
| Available external static pressure | Pa | 35(Initial static pressure with air filter : 5Pa) | |
| Exterior dimensions (H×W×D) | mm | 200×750×500 | |
| Net weight | kg | 20.5 | |
| Refrigerant piping size | Liquid / Gas | mm ⌀ | 6.35(1/4″) / 9.52(3/8″) |
| Bottom air inlet kit (option) | UT-BAT1EF | ||
| Outdoor unit | SRC25ZS-W2 | |||
| Power source | 1 Phase, 220 – 240V, 50Hz | |||
| Nominal cooling capacity (Min~Max) | kW | 2.5(1.0~3.0) | ||
| Nominal heating capacity (Min~Max) | kW | 3.2(0.9~4.4) | ||
| Power consumption | Cooling/Heating | kW | 0.62 / 0.80 | |
| EER/COP | Cooling/Heating | 4.03 / 4.00 | ||
| Max. running current | A | 9 | ||
| Sound power level | Outdoor | Cooling/Heating | dB(A) | 58 / 58 |
| Sound pressure level | Outdoor | Cooling/Heating | 46 / 46 | |
| Air flow | Outdoor | Cooling/Heating | m3/min | 27.4 / 23.6 |
| Exterior dimensions | Outdoor | HeightxWidthxDepth | mm | 540 x 780(+62) x 290 |
| Net weight | Outdoor | kg | 31.5 | |
| Refrigerant | Type/GWP | R410A / 2088 | ||
| Charge | kg/TCO2Eq | 0.75 / 1.566 | ||
| Refrigerant piping size | Liquid/Gas | ø mm | 6.35(1/4″) / 9.52(3/8″) | |
| Refrigerant line (one way) length | m | Max. 20 | ||
| Vertical height differences | Outdoor is higher/lower | m | Max. 10 / Max. 10 | |
| Outdoor operating temperature range | Cooling | ˚C | -15~46 | |
| Heating | -15~24 | |||
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.



Reviews
There are no reviews yet.