Description
INDOOR UNITS:
| Casing | Colour | White | |||
| Control systems | Infrared remote control | ARC480A53 | |||
| Wired remote control | BRC944B2 §$ BRC073A1 | ||||
| Dimensions | Unit | Depth | 225 | mm | |
| Height | 286 | mm | |||
| Width | 770 | mm | |||
| Fan | Air flow rate | Cooling | High | 9.5 | m³/min |
| Medium | 7.4 | m³/min | |||
| Low | 5.6 | m³/min | |||
| Silent operation | 4.2 | m³/min | |||
| Heating | High | 10.4 | m³/min | ||
| Medium | 8.1 | m³/min | |||
| Low | 6.2 | m³/min | |||
| Silent operation | 5.2 | m³/min | |||
| Piping connections | Drain | 18 | |||
| Gas | OD | 9.50 | mm | ||
| Liquid | OD | 6.35 | mm | ||
| Power input | Cooling | Nom. | 0.019 | kW | |
| Power supply | Frequency | 50 | Hz | ||
| Phase | 1~ | ||||
| Voltage | 220-240 | V | |||
| Sound power level | Cooling | 55 | dBA | ||
| Heating | Heating | 55 | dBA | ||
| Sound pressure level | Cooling | High | 39 | dBA | |
| Low | 25 | dBA | |||
| Medium | 33 | dBA | |||
| Silent operation | 19 | dBA | |||
| Heating | High | 39 | dBA | ||
| Low | 28 | dBA | |||
| Medium | 34 | dBA | |||
| Silent operation | 21 | dBA | |||
| Weight | Unit | 8.50 | kg | ||
OUTDOOR UNIT:
| Compressor | Type | Hermetically sealed swing compressor | ||||
| Dimensions | Unit | Depth | 350 | mm | ||
| Height | 552 | mm | ||||
| Width | 852 | mm | ||||
| Operation range | Cooling | Ambient | Min. | -10 | °CDB | |
| Max. | 46 | °CDB | ||||
| Piping connections | Additional refrigerant charge | 0.02 (for piping length exceeding 20m) | kg/m | |||
| Level difference | IU | OU | Max. | 15 | m | |
| IU | Max. | 7.5 | m | |||
| Total piping length | System | Actual | 30 | m | ||
| Power supply | Frequency | 50 | Hz | |||
| Phase | 1~ | |||||
| Voltage | 220-240 | V | ||||
| Refrigerant | Charge | 0.88 | kg | |||
| GWP | 675 | |||||
| Type | R-32 | |||||
| Sound pressure level | Cooling | Nom. | 46 | dBA | ||
| Heating | Nom. | 48 | dBA | |||
| Weight | Unit | 36 | kg | |||
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.



Reviews
There are no reviews yet.